Installation instructions for Linesse Quick Step floors
 
  1. When installing laminate floors in large rooms make sure to place expansion joints every 13 m width-wise and every 13m length-wise. Also, it is preferable that you provide expansion joints between different rooms. They can be finished using moldings attached to the subfloors.
  2. Never allow the end joints of to successive rows to be in line by staggering them by at least 10 cm.
  3. We recommend you purchase a few extra cartons of flooring, which will come useful in case of damaged planks, miscalculation of the room and further repairs.
arrow Preparing the room
  • Check that doors can still open after you install the underlayment and the floor
  • Check to see whether the molding can be removed. The floor can also be finished with Quick Step profiles.
  • The floor of the room should be flat. Please make sure you have smoothed out any unevenness.
  • The subfloor must be clean and dry.
arrow CONCRETE SUBFLOOR
New construction:
  • Make sure to allow the new concrete floor to dry for a week if it is of 1 – 4 cm thick and the double amount of time for a thickness of over 4 cm.
  • If you are installing the laminate flooring in a room with underfloor heating, make sure that the subfloor does not exceed the temperature of 28°C and that the moisture content is less than 1.5% and make sure to ask for special instructions or use a professional for the installation.
Renovation:
  • Remove any type of flooring (carpet, needle felt, etc)
  • If the previous flooring is damp sealed (PVC, linoleum, VCT, etc.) you do not have to remove it.
  • Make sure to always use underlayment. For optimal results, use Quick Step underlayment.
arrow WOODEN SUBFLOOR
  • First remove any previous flooring
  • Check to see whether the plank floor is stable and nail down any loose planks and use special leveling layers if necessary.
  • The Quick Step planks must be installed crosswise to the direction of previous floors.
  • Make sure that the crawl space under the laminate flooring has sufficient ventilation by removing any obstacles. The maximum moisture content of the wood must not exceed 12%.
arrow Installing the floor
arrow Step 1
Install the Quick Step underlayment per width and as you progress. Before cutting it to size, let it run up the wall a bit.

As the first floor strip is affixed to the floor panel, the two other strips must be clicked into it. Slide the strip and cut the panel. See fig. 2-6